  50-watt half-brick hbs50 dc-dc series data sheet rev. jun 04, 2004 efficiency vs. load (24v input ) technical specifications hbs dc-dc converters provide up to 50 watts of output power in an industry-standard, half-brick footprint. the hbs units feature excellent efficiency, class a conducted noise specs, and fixed switching frequency. the hbs, using open-frame packaging, along with planar magnetics provides maximum useable power with minimal thermal constraints. the hbs series is especially suited to telecom, networking, and industrial applications. description ? industry-standard half-brick ? open-frame packaging ? 100c baseplate operation ? water washable ? ?true-trim? option ? 1500v isolation ? positive or negative logic features notes ? mtbf predictions may vary slightly from model to model. specifications typically at 25c, normal line, and full load, unless otherwise stated. soldering conditions: i/o pins, 260c, ten seconds; fully compatible with commercial wave-soldering equipment. safety: agency approvals may vary from model to model. please consult factory for specific model information. units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. setpoint accuracy 1% line regulation v in min. - v in max., i out rated 0.2% v out load regulation i out min. - i out max., v in nom. 0.2% v out remote sense headroom 0.5 vdc minimum output current 10%, i out rated dynamic regulation, loadstep 25% i out pk deviation 4% v out settling time 500 ms voltage trim range 10% short circuit / overcurrent protection hiccup current limit threshold range, % of i out rated 110 - 140% ovp trip range 115 - 140% v out nom. ovp hiccup output voltage range 24 vdc nominal 18 - 36 vdc 48 vdc nominal 34 - 75 vdc reflected ripple 25 ma input reverse voltage protection shunt diode input 60 65 70 75 80 85 90 95 10 20 30 40 50 60 70 80 90 100 load % hbs050zg-a hbs050zh-a hbs050z10.5-a 60 65 70 75 80 85 90 95 10 20 30 40 50 60 70 80 90 100 load % efficiency % hbs050yg-a hbs050yh-a hbs050yj-a efficiency vs. load (48v input) turn-on time 10 ms remote shutdown positive or negative logic remote shutdown reference v in negative switching frequency 500 khz isolation input - output 1500 vdc input - case 1050 vdc output - case 500 vdc temperature coefficient 0.2%/c case temperature operating range -40 to +100c storage range -40 to +125c thermal shutdown range 105 to 115c vibration, 3 axes, 5 min each 5 g, 10 - 55 hz mtbf ? (bellcore tr-nwt-000332) 2.1 x 10 6 hrs safety ul, cul weight (approx.) 2.5 oz general page 1 of 3
50-watt half-brick hbs50 dc-dc series data sheet page 2 of 3 rev. jun 04, 2004 model input voltage input voltage maximum input output rated output ripple & noise typical (volts) range (volts) current (amps)* voltage (volts) current (amps) pk-pk (mv) efficiency** hbs050ye-a 24 18-36 3.50 3.3 15 100 80% hbs033ye-a 24 18-36 2.30 3.3 10 100 80% hbs050yg-a 24 18-36 3.60 5 10 100 84% hbs050yh-a 24 18-36 3.50 12 4.2 150 85% hbs050yj-a 24 18-36 3.50 15 3.3 150 86% hbs050ze-a 48 34-75 1.32 3.3 15 100 80% hbs033ze-ant 48 34-75 1.22 3.3 10 100 80% hbs050zg-a 48 34-75 1.80 5 10 100 82% hbs050zh-a 48 34-75 1.75 12 4.2 150 85% hbs050zj-at 48 34-75 1.75 15 3.3 150 87% notes: * maximum input current at minimum input voltage, maximum rated output power. ** at nominal v in , rated output. model selection  

 

 


 
 
 
 
 

      
! 
  !       
 
 


 


 "
#$
#$
 
 
! 
 
!   thermal impedance natural convection 6.6 c/w 100 lfm 5.7 c/w 200 lfm 4.2 c/w 300 lfm 3.1 c/w 400 lfm 2.6 c/w tolerances note: thermal impedance data is dependent on many environmental factors. the exact thermal performance should be validated for specific application. 1-v in 2 case 3 on/off 4+v in 5-v out 6 -sense 7 trim 8 +sense 9+v out inches: (millimeters) .xx 0.020 .x 0.5 .xxx 0.010 .xx 0.25 pin: 0.002 0.05 (dimensions as listed unless otherwise specified.) pin function mechanical drawing model numbers highlighted in yellow or shaded are not recommended for new designs.
page 3 of 3 rev. jun 04, 2004 options this page is offered as a reference. consult factory for actual availability of options. when ordering equipment options, use the following suffix information. select preferred option(s) and add the suffix to the model number. ordering option examples are located below the options table. example options: hbs050zg-ant3v = hbs050zg-a with negative logic, lucent-compatible trim, and 0.95? vertical heatsink. les015yj-3n = les015yj with optional trim and enable, negative logic. qbs066zg-at8 = qbs066zg-a with lucent-compatible trim and 0.110? pin length. nuclear and medical applications - power-one products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divi sional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice. option suffix applicable series remarks negative logic n has, hbd, hbs, hes, hls, hld, les, ttl "low" turns module on qbs, qes, qls, tes, tqd ttl "high" turns module off lucent-compatible trim t has, hbd, hbs, hes, hls, qbs, qes, qls trim 1 ias, les enable 2 iad, ias, les, sms trim and enable 3 ias, les pin length and heatsink options standard pin length is 0.180" (4.6mm) 0.110" (2.8mm) pin length 8 all leaded models 0.150" (3.8mm) pin length 9 all leaded models 0.24" (6.1mm) horizontal heatsink 1h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.24" (6.1mm) vertical heatsink 1v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) horizontal heatsink 2h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) vertical heatsink 2v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) horizontal heatsink 3h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) vertical heatsink 3v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages)


▲Up To Search▲   

 
Price & Availability of HBS050YH-A2V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X